FUEL & CHEMICAL PROCESSES ›› 2015, Vol. 46 ›› Issue (3): 57-59.

Previous Articles     Next Articles

Modification of replacing traditional trays with new type vertical sieve trays for ammonia stripping system

Zhong Jisheng   

  1. Coke Plant of Xuanhua Steel Company of Hebei Iron & Steel Group,Xuanhua 075100,China
  • Online:2015-05-28

Abstract:

On condition of not changing the column body of original ammonia stripper and deacidifier,this paper presents the method of replacing original internals with new type vertical sieve trays,which has solved the problem of insufficient capacity and effect of ammonia stripping process.The capacity could be increased to 200~280m3/h from 133m3/h,and at the same time the parameters of ammonia stripping and deacidifier could meet the requirement of original design,so that it has achieved the effect of high yield with lower energy consumption.

CLC Number: