FUEL & CHEMICAL PROCESSES ›› 2015, Vol. 46 ›› Issue (3): 55-56.

Previous Articles     Next Articles

Methods of reducing total cyanide concentration in coke plant wastewater

Sun Hongyan1  Liu Wuyong2   

  1. 1.Beiying Coke Plant of BX Steel Group,Benxi 117017,China; 2.Supplier Management Department of BX Steel Group,Benxi 117017,China
  • Online:2015-05-28

Abstract:

This paper introduces the three methods of reducing total cyanide concentration in coke plant wastewater.The test shows that the methods of coke absorption and flocculant dosing to oil removal tank are both effective.Coke absorption method will increase labor intensity,so it is not a good option; while the method of dosing flocculant to oil removal tank with self-pressure blowdown system could not only reduce the total cyanide concentration and also benefit the biochemical treatment process.

CLC Number: