FUEL & CHEMICAL PROCESSES ›› 2019, Vol. 50 ›› Issue (1): 23-26.

Previous Articles     Next Articles

Feasibility study for cyclone dust collector as primary deduster for CDQ unit

Zhang Jiamin1  Zhu Canpeng1  Zheng Mingdong2   

  1. 1.Beijing Shougang International Engineering Technology Co.,Ltd.,Beijing 100043,China; 2.Anhui University of Science & Technology,Huainan 232001,China
  • Online:2019-01-23

Abstract:

Based on the theory of fluid mechanics and by calculation and comparison between cyclone dust collector and gravity dust collector,confinement reasons are found for holding back the cyclone collector as primary deduster for CDQ unit.Design selection,fabrication,installation and execution result,etc.in practice are introduced.The study result shows that the cyclone collector can replace the conventional primary deduster even the secondary one in the CDQ unit,and can meet the process requirement with features such as simple process flow,low investment and good performance,etc.,with dust content in circulating gas lower than 1 g/m3.

CLC Number: