Abstract:
The process of phenol-cynaide-containing waste water treatment in coking plants is introduced.The reasons for the high ammonia nitrogen concentration in waste water after bio-chemical treatment of phenol-cynaide-containing waste water are analyzed.Based on the analysis result,improvement measures are taken,after which the ammonia nitrogen concentration meets the design requirement.
CLC Number:
X784
Sun Hongyan1 Zhang Chengzhan1 Liu Wuyong2. Practice of decreasing the ammonia nitrogen concentration in waste water after AAO treatment[J]. FUEL & CHEMICAL PROCESSES, 2018, 49(4): 49-50.