Analysis and control of advanced treatment of coking waste water by Fenton oxidation process

Ma Lei   

  1. Tangshan Iron & Steel Co.,Ltd.,Tangshan 063000,China
  • Online:2017-07-20

Abstract:

Fenton oxidation process is used for the advanced treatment of coking waste water.After treatment,the indexes of the waste water are as follows: COD:60~70mg/L,ammonia nitrogen <5mg/L,suspended matter:15~30mg/L.The quality of discharged water meets the requirements stipulated in national standard GB16171—2012 Emission standard of pollutants for coking chemical industry.