FUEL & CHEMICAL PROCESSES ›› 2014, Vol. 45 ›› Issue (5): 40-44.
Previous Articles Next Articles
Yuan Maobiao Jin Man Ding Jianqiang
Online:
Abstract:
This paper studies the influencing factors such as microwave processing time,microwave power,FeSO4 dosing amount,H2O2 dosing amount,H2O2 dosing times and pH value during coking wastewater treatment by Microwave-Fenton oxidation.The optimum process conditions are determined by the experiment:pH value of wastewater:3,FeSO4 dosing amount:300mg/L,H2O2 total dosing amount of H2O2:900mg/L,H2O2 dosing times:3,microwave power:500W,temperature:50℃,reaction time:30min.the removal rate of turbidity,chroma and COD are 97.59%,95.62% and 86.21% respectively.The wastewater after treatment is clear,and the remaining COD is 50.34mg/L.The turbidity,chroma and COD meet the requirement of industrial recirculating water standard.
CLC Number:
X784
Yuan Maobiao Jin Man Ding Jianqiang. Study on coking wastewater treatment by Microwave-Fenton oxidation[J]. FUEL & CHEMICAL PROCESSES, 2014, 45(5): 40-44.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: https://journal03.magtechjournal.com/Jwk3_rlyhg/EN/
https://journal03.magtechjournal.com/Jwk3_rlyhg/EN/Y2014/V45/I5/40