干熄焦冷却套管堵塞原因及结渣物分析

邵仪先1  白新革1  李志华1  吕青青1  景阳2   

  1. 1.沙钢集团焦化厂, 张家港215625; 2.中冶焦耐工程技术有限公司, 大连116085
  • 出版日期:2016-11-11

Reason for the blockage of CDQ cooling sleeve and slag analysis

Shao Yixian1  Bai Xinge1  Li Zhihua1  Lü Qingqing1  Jing Yang2   

  1. 1.Coking Plant of Shagang Group,Zhangjiagang 215625,China; 2.ACRE Coking & Refractory Engineering Consulting Corporation,MCC,Dalian 116085,China
  • Online:2016-11-11

摘要:

分析了140t/h干熄焦一次除尘器冷却套管在运行中发生堵塞而影响正常生产的原因,通过对结渣物进行理化试验分析,得出了堵塞物形成的机理,经过现场优化工艺操作等技术和管理手段,控制了冷却套管结渣现象。

Abstract:

This paper analyzes the reason for the blockage of 140t/h CDQ cooling sleeve during operation.Through physical and chemical analysis on the slag,the reason for slag forming was found out.The problem of slag formation in the cooling sleeve was solved by optimizing the field operation and management.

中图分类号: