FUEL & CHEMICAL PROCESSES ›› 2021, Vol. 52 ›› Issue (3): 19-20.

Previous Articles     Next Articles

Coke moisture control during annual maintenance for CDQ system and its performance#br#

Wang Hongshun  Gao Lidong  Xiang Haifei  Han Kuang  Gao Fenglin   

  1. Anyang Iron & Steel Co.,Ltd.,Anyang 455004,China
  • Online:2021-05-23 Published:2021-07-08

Abstract:

During annual maintenance for CDQ system in Anyang Iron & Steel,the coke moisture stays high and fluctuates.In view of the factors influencing the coke moisture,measures were taken such as to standardize coke receiving by quenching car,to control dewatering time and coke discharging on the coke wharf,to optimize quenching time for high and low water volume,as well as to minimize the quenching water volume to maintain the coke moisture around 8% on the premise of no red hot coke so as to ensure stable operation of blast furnace.

Key words: CDQ, Coke moisture, Quenching water volume, Coke drying time

CLC Number: