FUEL & CHEMICAL PROCESSES ›› 2018, Vol. 49 ›› Issue (6): 22-23.

Previous Articles     Next Articles

Application of improving dry quenching rate for 2# CDQ unit

Zhao HuaZhou PengMa YinhuaLi XuedongDai Cheng (   

  1. Coking Plant of Bayuquan Iron & Steel Company,Ansteel Co.,Ltd.,Yingkou 115007,China
  • Online:2018-11-23

Abstract:

Obstacles affecting 2# CDQ unit production are introduced.The dry quenching rate for 2# CDQ unit is calibrated on site,including technical modifications.The modified 2# CDQ unit has a lower temperature of the coke discharged,uniformly distributed coke and higher coke discharging capacity,etc.,with dry quenching rate increased from 88.68% up to more than 93%.The CDQ capacity is gradually increased.

CLC Number: