Coke flow and heat transfer process in CDQ chamber

Jin Minglin1  Jin Shuangling1  Cao Yinping2  Liu Jie2  Yu Guopu2   

  1. 1.Shanghai Application Technology Institute,Shanghai 201408,China; 2.Iron-making Plant of Baosteel Co.,Ltd.,Shanghai 200941,China
  • Online:2015-11-12

Abstract:

Study on the flow and heat transfer process shows that the zero pressure level of CDQ system is located in the corbel zone,so the distribution of gas flow in the cooling chamber is not only related to the voidage of moving coke bed,but also related to the layout of regulating bricks at the outlet of corbel zone and negative pressure.Heat transfer between gas and coke in CDQ chamber can be enhanced by prolonging the stay of carrier gas in high temperature area and improving the gas flow distribution between the carrier gas and coke in the low temperature area.