FUEL & CHEMICAL PROCESSES ›› 2015, Vol. 46 ›› Issue (1): 56-58.
Previous Articles Next Articles
Li Changyin Tan Xiao Pang Keliang Zhu Qingmiao Bian Zifeng
Online:
Abstract:
Experiments have been conducted to compare phosphate treatment and equilibrium phosphate treatment.The result shows that by adopting equilibrium phosphate treatment,the high temperature and high pressure boiler runs stably with higher quality water and steam,and dosing amount of secondary ammonia to boiler feed water is reduced,hidden of phosphate is prevented and chemical dosing times and quantity are reduced.
CLC Number:
X784
Li Changyin Tan Xiao Pang Keliang Zhu Qingmiao Bian Zifeng. Applicationof equilibrium phosphate treatment in high temperature and high pressure boiler[J]. FUEL & CHEMICAL PROCESSES, 2015, 46(1): 56-58.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: https://journal03.magtechjournal.com/Jwk3_rlyhg/EN/
https://journal03.magtechjournal.com/Jwk3_rlyhg/EN/Y2015/V46/I1/56