FUEL & CHEMICAL PROCESSES ›› 2015, Vol. 46 ›› Issue (1): 56-58.

Previous Articles     Next Articles

Applicationof equilibrium phosphate treatment in high temperature and high pressure boiler

Li Changyin  Tan Xiao  Pang Keliang  Zhu Qingmiao  Bian Zifeng   

  1. Coking Plant of Anshan Iron and Steel Company,Anshan 114002,China
  • Online:2015-01-10

Abstract:

Experiments have been conducted to compare phosphate treatment and equilibrium phosphate treatment.The result shows that by adopting equilibrium phosphate treatment,the high temperature and high pressure boiler runs stably with higher quality water and steam,and dosing amount of secondary ammonia to boiler feed water is reduced,hidden of phosphate is prevented and chemical dosing times and quantity are reduced.

CLC Number: