Analysis on elevated water pump for wet quenching

Gong Junku  Zhang Liming  Bai Jian  Bai Yinshi  Li Huafeng   

  1. ACRE Coking & Refractory Engineering Consulting Corporation,MCC,Dalian 116085,China
  • Online:2014-05-20

Abstract:

Wet quenching water pump is raised by calculating to solve the maintenance difficulty due to original low position.Whether the water pump is installed above ground or not is related to local atmosphere (ATM) and installation elevation depends on ATM,necessary NPSH as well as suction resistance of pipe.