FUEL & CHEMICAL PROCESSES ›› 2016, Vol. 47 ›› Issue (3): 47-49.

Previous Articles     Next Articles

Effect of CMC on gas purification system

Peng Guangwen   

  1. Liuzhou Iron & Steel Co.,Ltd.,Liuzhou 545002,China
  • Online:2016-05-20

Abstract:

The application of coal moisture control (CMC) through built-in fluidized bed will lead to the increase of gas transport resistance and quality fluctuation of by\|products.After the implementation of some preventive and corrective measures in the gas purification system,blockage inside the pipeline and column can be avoided.As a result, high quality of by-products can be maintained.

CLC Number: