FUEL & CHEMICAL PROCESSES ›› 2013, Vol. 44 ›› Issue (3): 18-19.
Previous Articles Next Articles
Guo Lin Yu Yongwei Liu Sukun Yue Dayong Zhang Tao
Online:
Abstract:
Due to the problems in the coal tower structure of 5.5m stamp-charging battery in design and construction,it gives rise to abnormalities,such as vertical cracks at brackets overhanging from the deep beam,vibration feeders resonation and imbalanced bracing systems of scaffold,etc..This paper analyzes the causes of the problems and gives solutions such as mending bracket’s crack,adding shear wall and improving the bracing systems of scaffold,etc.for treatment of the structural defects.
CLC Number:
TQ522.15
Guo Lin Yu Yongwei Liu Sukun Yue Dayong Zhang Tao. Treatment and study of the structural defects for the coal tower of 5.5m stamp-charging battery[J]. FUEL & CHEMICAL PROCESSES, 2013, 44(3): 18-19.