脱硫液变黑原因分析及解决办法

宋冬1,2  陈红萍1   

  1. 1.华北理工大学化学工程学院 , 唐山063000;2.首钢京唐西山焦化有限责任公司, 唐山063200
  • 出版日期:2017-07-20

Analysis and solution to the blackening of desulfurization liquid

1.School of Chemical Engineering of North China University of Science and Technology,Tangshan 063000,China; 2.Xishan Coking Co.,Ltd.of Shougang Group,Tangshan 063200,China   

  • Online:2017-07-20

摘要:

分析真空碳酸钾脱硫工艺脱硫液变黑的原因为煤气中氨含量超标。在脱硫塔旁设置缓冲罐置换变黑的脱硫液,同时控制进口煤气中氨含量,能有效解决脱硫液变黑的问题,稳定生产。

Abstract:

It is analyzed in this paper that the blackening of vacuum potassium carbonate desulfurization liquid resulted from excessive high content of ammonia in gas.A solution is proposed that a buffer tank is installed by the desulfurization column for changing the blackened desulfurization liquid and controlling the ammonia content at the gas inlet which could effectively solve the problem and stabilize production.