燃料与化工 ›› 2023, Vol. 54 ›› Issue (5): 28-32.

• 煤焦技术 • 上一篇    下一篇

干熄焦一、二次除尘器焦粉收集系统研究

  

  1. (北京中日联节能环保工程技术有限公司,北京 100040
  • 出版日期:2023-09-23 发布日期:2023-09-13

Research on coke breeze collection system of the primary and secondary dust
catcher for CDQ

  1. (Beijing JC Energy & Environment Engineering Co.,Ltd.,Beijing 100040,China)
  • Online:2023-09-23 Published:2023-09-13

摘要:

从焦粉收集量与输灰设备能力匹配方面进行研究,并对刮板机方案和气力输送方案设备配置、一次投资、
运行费用、工艺方案的优缺点等进行充分比较,可为今后干熄焦输灰系统的设置提供理论依据,并有利于改善
环境。

关键词:

Abstract:

This paper studies the matching between collection quantity of coke breeze and capacity of dust conveying equipment,and compares the equipment configuration,one time investment,operating cost and the advantages and disadvantages of the process of scraper and pneumatic conveying scheme,which can provide theoretical basis for provision of CDQ dust conveying system in the future and benefit for environment improvement.

Key words:

"> font-family:方正书宋_GBK, font-size:10pt, ">Primary and secondary dust catcher, Coke breeze collection system, Equipment selection

"> font-family:方正书宋_GBK, font-size:10pt, ">and control, Scraper scheme, Pneumatic conveying scheme

中图分类号: 

" target="_blank"> ">TQ520.5