燃料与化工 ›› 2014, Vol. 45 ›› Issue (5): 30-31.
• 煤焦技术 • 上一篇 下一篇
武克学
出版日期:
Wu Kexue
Online:
摘要:
介绍了干熄炉水封槽的损坏原因及改进方法,改进后水封槽积垢较厚,但整体结构未发生实质变化,使用寿命可达4年以上。
Abstract:
This paper introduced the causes of damage of water seal tank for CDQ and its improvement method.Although improved water seal tank accumulates a thicker fouling,the overall structure has not suffered from any substantial change,with service life over four years.
中图分类号:
TQ520.5
武克学. 干熄炉水封槽的损坏原因与改进[J]. 燃料与化工, 2014, 45(5): 30-31.
Wu Kexue. Cause of damage to CDQ water seal tank and its improvement[J]. FUEL & CHEMICAL PROCESSES, 2014, 45(5): 30-31.
0 / / 推荐
导出引用管理器 EndNote|Reference Manager|ProCite|BibTeX|RefWorks
链接本文: https://journal03.magtechjournal.com/Jwk3_rlyhg/CN/
https://journal03.magtechjournal.com/Jwk3_rlyhg/CN/Y2014/V45/I5/30