燃料与化工 ›› 2013, Vol. 44 ›› Issue (4): 22-23.
• 煤焦技术 • 上一篇 下一篇
曲鹏 方毅 高禹 尚世宇
出版日期:
Qu Peng Fang Yi Gao Yu Shang Shiyu
Online:
摘要:
针对焦炉除尘系统刮板输送机的保护装置存在的问题,通过取消中间继电器或选用三线制接近开关进行改进,可减少投资,降低故障率,接线简单可靠,有利于提高除尘系统运行的可靠性和稳定性。
Abstract:
According to the fact that some problems are found in the protection system of scraper conveyor for coke oven dedusting system,this paper proposes an improvement by canceling the intermediate relay or by using three-wire proximity switch,which is characterized with low cost,less failure and reliable wiring so that reliability and stability of the dedusting system can be remarkably improved.
中图分类号:
TQ520.5
曲鹏 方毅 高禹 尚世宇. 焦炉除尘系统刮板机断链保护的改进[J]. 燃料与化工, 2013, 44(4): 22-23.