燃料与化工 ›› 2010, Vol. 41 ›› Issue (5): 16-18.
• 煤焦技术 • 上一篇 下一篇
刘晓东,王慧璐,李 刚,王 黎
出版日期:
Liu Xiaodong,Wang Huilu,Li Gang,Wang Li
Online:
摘要:
介绍了蓄热室顶部测温补偿条件、补偿方法、选取条件和注意事项。当需要采取蓄顶测温补偿时,可以通过比较横墙和直行的均匀系数选择蓄顶测温补偿方案。对横墙均匀系数较好的炉号选择异侧补偿方法,其余选择同侧补偿方法。
Abstract:
The compensation condition, compensation method, selection condition and precaution of temperature measurement on top of coke oven regenerator were described. When the temperature measurement on top of regenerator is required to be compensated, the compensation proposal of temperature measurement on top of regenerator is selected by compensation of lateral temperature and longitudinal temperature uniform factor. For oven number with better uniform factor of lateral temperature, hetero-side compensation method is selected, for others, homo-side compensation method is selected.
中图分类号:
TP212
刘晓东,王慧璐,李 刚,王 黎. 焦炉蓄热室顶部测温补偿模型研究[J]. 燃料与化工, 2010, 41(5): 16-18.
0 / / 推荐
导出引用管理器 EndNote|Reference Manager|ProCite|BibTeX|RefWorks
链接本文: https://journal03.magtechjournal.com/Jwk3_rlyhg/CN/
https://journal03.magtechjournal.com/Jwk3_rlyhg/CN/Y2010/V41/I5/16