FUEL & CHEMICAL PROCESSES ›› 2014, Vol. 45 ›› Issue (3): 51-53.

Previous Articles     Next Articles

Analysis and countermeasures of wash oil crystallization in benzol scrubbing system under negative pressure

Peng Guangwen   

  1. Liuzhou Iron & Steel Co.,Ltd.- Coking Plant,Liuzhou 545002,China
  • Online:2014-05-20

Abstract:

In this paper,problems in benzol scrubbing system under negative pressure are analyzed.Based on behaviors of crystals,process parameters are adjusted to solve improper temperature control,low efficiency of wash oil regeneration as well as blockage due to long time crystal deposit.Normal production can be resumed as a result.

CLC Number: