FUEL & CHEMICAL PROCESSES ›› 2010, Vol. 41 ›› Issue (4): 18-21.

Previous Articles     Next Articles

Optimization of PROven system parameters for 7.63m coke oven

Chen Yucun,Qiu Quanshan,Qian Hulin,Wu Hongjie   

  1. Coal & Coking Company of Masteel, Ma’anshan 243021, China
  • Online:2010-07-23

Abstract:

Aiming at the many problems occurred during the production test run of PROven system, the Coking Plant of Masteel has done a series of optimizations of its design parameters during its actual application so as to make PROven system functions more perfect. The optimized PROven system has not only solved the gas escaping problem on site, but also shortened the automatic interlocking time of charging car and PROven system. This can avoid the misoperation of operator and increase the safety and reliability of production operation.

CLC Number: