燃料与化工 ›› 2011, Vol. 42 ›› Issue (6): 42-44.

• 煤气净化与化学产品加工 • 上一篇    下一篇

UV254在焦化废水处理中的应用

鲍秀瑾1   邵争辉2   武献春1   李丽敏1   

  1. 1.煤基低碳能源国家重点实验室,廊坊 065000;
    2.中国质量认证中心,北京 100070
  • 出版日期:2011-11-30

Application of UV254 in coking wastewater treatment

Bao Xiujin1    Shao Zhenghui2    Wu Xianchun1    Li Limin1   

  1. 1.State Key Laboratory for Coal-based Low Carbon Energy, Langfang 065000, China;
    2. China Quality Authentification Center, Beijing 100070, China
  • Online:2011-11-30

摘要:

本文研究了焦化废水处理过程中COD和UV254值的相关性。结果表明,生化系统出水及深度处理出水的COD和UV254值具有很好的相关性,相关性系数约为0.988,可以通过快速测定UV254值预测深度处理效果。

Abstract:

The correlativity between COD and UV254 value during the treatment of coking wastewater is studied in the paper. The result shows that the COD and UV254 values of the water discharged from the biological system and of the water after further treatment have very good correlativity and the correlativity factor is about 0.988. The further treatment result can be predicted through the quickly measurement of the value of UV254.